Feature: Screw block with single stage air compression Advantages: Low compression level Low temperature rise Low air leakage Integrated shaft (direct drive) Benefit: 5% energy saving Feature: IE4 Permanent Magnet Motor / WEG Brand High Efficiency IE4 Motor Optional oil cooled engine Advantages : Engine efficiency 97% Benefit: 5% energy saving

title_icon5_whiteVision Air

Product advantages

🎗
service_block_4

Feature

Feature: Dual VFD System Benefits : Constant pressure output to eliminate pressure fluctuations and load shedding Constant outlet temperature at 80-85℃ Low inrush current to protect components Benefit: 15% energy savings

🎗
service_block_4

Benefits

Feature: Screw block with single stage air compression Advantages: Low compression level Low temperature rise Low air leakage Integrated shaft (direct drive) Benefit: 5% energy saving

🎗
service_block_4

Advantages

Feature: Dual VFD System Benefits : Constant pressure output to eliminate pressure fluctuations and load shedding Constant outlet temperature at 80-85℃ Low inrush current to protect components Benefit: 15% energy savings

ModelMaximum Working PressureProductivity (fad)Power
Electric motor
Appearance
Transmission
Noise LevelDiameter
Pipes
Exports
RefrigeratorSize (mm)Wes
barpsigm³/mincfmkwhpdbinchLLInHkg
SVC-15A II.4.5651.0~3.935.3~137.71520Straight
drive
651 1/224155098013001000
5.5800.9~3.531.8~123.6
6.5940.8~3.228.2~113.0
7.51090.7~3.024.7~105.9
8.51230.7~2.924.7~102.4
10.51520.6~2.421.2~84.7
12.51810.5~2.017.7~70.6
SVC-18A II.4.5651.2~4.842.4~169.418.525Straight
drive
651 1/224155098013001100
5.5801.1~4.338.8~151.8
6.5941.0~4.035.3~141.2
7.51090.9~3.831.8~134.1
8.51230.8~3.428.2~120.0
10.51520.7~2.924.7~102.4
12.51810.7~2.724.7~95.3
SVC-22A II.4.5651.6~6.456.5~225.92230Straight
drive
652501700113014301300
5.5801.5~6.153.0~215.3
6.5941.2~4.842.4~169.41 1/224155098013001100
7.51091.1~4.538.8~158.9
8.51231.1~4.338.8~151.8
10.51520.8~3.428.2~120.0
12.51810.7~2.924.7~102.4
SVC-30A II.4.5652.1~8.874.1~310.73040Straight
drive
682501700113014301350
5.5801.9~7.767.1~271.8
6.5941.8~7.063.5~247.1
7.51091.6~6.856.5~240.0
8.51231.5~6.253.0~218.9
10.51521.2~4.742.4~165.91 1/224155098013001150
12.51811.1~4.338.8~151.8
SVC-37A II.4.5652.6~10.391.8~363.63750Straight
drive
682501850118014301650
5.5802.4~9.584.7~335.4
6.5942.2~8.777.7~307.11700113014301450
7.51091.9~7.567.1~264.8
8.51231.8~7.463.5~261.2
10.51521.5~6.053.0~211.8
12.51811.4~5.649.4~197.7
SVC-45A II.4.5653.3~13.1116.5~462.44560Straight
drive
682 1/2702250137017002300
6.5802.9~11.5102.4~405.9
6.5942.4~10.584.7~370.62501850118014302000
7.51092.3~10.081.2~353.01700113014601650
8.51232.2~8.677.7~303.6
10.51521.9~7.567.1~264.8
12.51811.6~6.456.5~225.9
ModelMaximum Working PressureProductivity (fad)Power
Electric motor
Appearance
Transmission
Noise LevelDiameter
Pipes
Exports
RefrigeratorSize (mm)Wes
barpsigm³/mincfmkwhpdbinchLLInHkg
SVC-150A/W II.4.56510.5~42.0370.7~1482.6150200Straight
drive
78DN1251503250
(3250)
1950
(1950)
2150
(2150)
5800
(5500)
5.5809.6~38.3338.9~1352.0
6.5948.8~35.0310.6~1235.5
7.51098.1~33.0285.9~1164.9
8.51237.4~30.0261.2~1059.0DN1001202900
(2900)
1940
(1940)
1950
(1950)
4700
(4300)
10.51526.5~28.0229.5~988.4
12.51816.1~24.3215.3~857.8
SVC-160A/W II.4.56511.0~44.0388.3~1553.2160215Straight
drive
78DN1251503250
(3250)
1950
(1950)
2150
(2150)
6100
(5800)
5.58010.5~42.0370.7~1482.6
6.5949.6~38.3338.9~1352.0
7.51098.8~35.0310.6~1235.5
8.51238.1~33.0285.9~1164.9
10.51527.7~30.0271.8~1059.0DN1001202900
(2900)
1940
(1940)
1950
(1950)
4800
(4400)
12.51816.5~26.3229.5~928.4
SVC-185A/W II.4.56512.7~50.0448.3~1765.0185250Straight
drive
78DN1251803500
(3500)
2250
(2100)
2300
(2400)
7200
(6400)
5.58011.5~46.0406.0~1623.81503250
(3250)
1950
(1950)
2150
(2150)
6500
(6200)
6.59411.0~44.0388.3~1553.2
7.510910.7~42.0377.7~1482.6
8.512310.3~40.0363.6~1412.0
10.51528.8~35.5310.6~1253.2
12.51817.5~32.4264.8~1143.7
SVC-200A/W II.4.56513.7~55.0483.6~1941.5200270Straight
drive
80DN1502003800
(3800)
2300
(2300)
2400
(2400)
8000
(8000)
5.58012.5~50.0441.3~1765.0DN1251803500
(3500)
2250
(2100)
2300
(2400)
7300
(6500)
6.59411.5~46.0406.0~1623.8
7.510911.0~44.0388.3~1553.2
8.512310.5~42.0370.7~1482.6
10.51529.7~38.6342.4~1362.6
12.51818.2~33.0289.5~1164.9
SVC-220A/W II.4.56515.3~61.0540.1~2153.3220300Straight
drive
80DN1502003800
(3800)
2300
(2300)
2400
(2400)
8200
(8200)
5.58013.7~55.0483.6~1941.5
6.59412.7~51.0448.3~1800.3
7.510912.4~49.6437.7~1750.9DN1251803500
(3500)
2250
(2100)
2300
(2400)
7500
(6600)
Model Maximum Working Pressure Productivity (fad) Power Electric motor Appearance Transmission Noise Level Diameter Pipes Exports Refrigerator Size (mm) Wes
bar psig m³/min cfm kw hp db inch L L In H kg
SVC-55A 7.5 109 2.75~11.00 97.08~388.30 55 75 Straight Drive 72 2 40 1400 1100 1510 950
8.5 123 2.58~10.30 91.07~363.59
10.5 152 2.18~8.70 76.95~307.11
12.5 181 2.00~8.00 70.60~282.40
SVC-75A 7.5 109 3.45~13.80 121.79~487.14 75 100 Straight Drive 72 2 60 1400 1100 1510 1000
8.5 123 3.25~13.00 114.73~458.90
10.5 152 2.88~11.50 101.66~405.95
12.5 181 2.55~10.60 90.02~374.18
SVC-90A/W 7.5 109 4.13~17.80 145.79~628.34 90 120 Straight Drive 75 DN65 70 2100 1370 1700 2000
8.5 123 4.00~17.20 141.20~607.16
10.5 152 3.48~14.60 122.84~515.38 2 2100 1370 1700 1900
12.5 181 3.08~12.30 108.72~434.19
SVC-110A/W 7.5 109 5.50~22.00 194.15~776.60 110 150 Straight Drive 75 DN65 100 2300 1550 1900 2400
8.5 123 5.13~21.00 181.09~741.30
10.5 152 4.47~18.00 157.79~635.40 2100 1370 1700 2200
12.5 181 3.70~14.80 130.61~522.44
SVC-132A/W 7.5 109 6.43~25.70 226.98~907.21 132 175 Straight Drive 78 DN80 100 2900 1890 1950 2800
8.5 123 6.13~24.50 216.39~864.85
10.5 152 5.35~21.40 188.86~755.42
12.5 181 4.45~17.80 157.09~628.34 DN65 2300 1550 1900 2600
SVC-160A/W 7.5 109 7.50~30.00 264.75~1059.00 160 215 Straight Drive 78 DN100 100 2900 1890 2050 3500
8.5 123 7.20~28.80 254.16~1016.64
10.5 152 5.87~23.50 207.21~829.55 DN80 2900 1890 1950 3000
12.5 181 5.25~21.00 185.33~741.30
SVC-185A/W 7.5 109 8.63~34.50 304.64~1217.85 185 250 Straight Drive 78 DN100 150 2900 1890 2050 4000
8.5 123 8.25~33.00 291.23~1164.90
10.5 152 7.20~28.80 254.16~1016.64
12.5 181 5.87~23.50 207.21~829.55 DN80 2900 1890 1950 3800
SVC-250A/W 7.5 109 10.90~43.80 384.77~1546.14 250 340 Straight Drive 82 DN125 150 3100 2000 2100 5200
8.5 123 10.70~43.00 377.71~1517.90
10.5 152 / / / / / / /
12.5 181 8.30~33.00 292.99~1164.90 DN100 2900 1890 2050 4800
ModelMaximum Working PressureProductivity (fad)Power
Electric motor
Appearance
Transmission
Noise LevelDiameter
Pipes
Exports
RefrigeratorSize (mm)Wes
barpsigm³/mincfmkwhpdbinchLLInHkg
SVC-250A/W II.4.56516.3~65.0575.4~2294.5250340Straight
drive
82DN1502003800
(3800)
2300
(2300)
2400
(2400)
8300
(8300)
5.58015.3~61.0540.1~2153.3
6.59415.0~60.0529.5~2118.0
7.510913.8~55.3487.1~1952.1
8.512313.3~51.0469.4~1800.3
10.515211.7~46.0413.0~1623.8DN1251803500
(3500)
2250
(2100)
2300
(2400)
7600
(6800)
12.518110.3~41.2363.6~1454.4
SVC-280A/W II.4.56519.2~76.9677.8~2714.6280375Straight
drive
82DN2002504300
(4000)
2400
(2400)
2600
(2650)
9000
(9000)
5.58017.8~71.0628.3~2506.3DN1502003800
(3800)
2300
(2300)
2400
(2400)
8500
(8600)
6.59416.2~65.0571.9~2294.5
7.510915.1~60.5533.0~2135.7
8.512314.1~56.5497.7~1994.5
10.515212.8~51.0451.8~1800.3
12.518111.6~46.0409.5~1623.8
SVC-300A/W II.4.56520.6~82.5727.2~2912.3300400Straight
drive
85DN2002504300
(4000)
2400
(2400)
2600
(2650)
9400
(9400)
5.58019.2~76.8677.8~2711.0
6.59417.7~70.9624.8~2502.8DN1502003800
(3800)
2300
(2300)
2400
(2400)
8800
(9000)
7.510916.2~65.0571.9~2294.5
8.512315.0~60.3529.5~2128.6
10.515214.1~56.5497.7~1994.5
12.518112.8~51.5451.8~1818.0
SVC-330A/W II.4.56521.3~85.5751.9~3018.2330440Straight
drive
85DN2002504300
(4000)
2400
(2400)
2600
(2650)
9800
(10000)
5.58020.6~82.4727.2~2908.7
6.59419.2~76.7677.8~2707.5
7.510917.7~70.7624.8~2495.7DN1502003800
(3800)
2300
(2300)
2400
(2400)
9200
(9500)